Electronic Features
1. Digital Control Program Features

• Digital controller and microprocessor for electronic programming with superior performance and process management.
• The Press automatically times the appropriate transfer duration for each Program for type of transfer. The display shows the countdown time or Press Cycles
• When the timer countdown is done the alarm chirps and the display flashes “DONE”.
• The first “cycle done” chirp is mutable for users who find it annoying.
• If the Heat Platen is not raised when the cycle is done the following alarms occur:
- 10 seconds late – 2 beeps
- 30 seconds late 5 beeps
- 40 seconds late - 20 beeps
- 60 seconds late - alarm stops and system resets to 250F
- 6 minutes late – system shuts down completely
• The IDek Press has 3 preset, customizable Programs for convenience
- P1 350 deg F 20 sec Vinyl Materials
- P2 375 deg F 15 sec Ink Jet Transfers
- P3 400 deg F 30 sec Sublimation
• P1, P2, P3 settings (above) can be customized
- Depressing the “PROG” key for 3 seconds allows the current temp and time settings to be edited using the up/down arrow keys. Exiting the programming session (Program key for 3 seconds) stores the new values.
• Manual Mode
- Time and Temp settings are at the immediate control of the user by depressing the “TIME” or “TEMP” key and the “UP”/ “DOWN” arrows keys.
- Low temp setting from 200 deg F to 410 deg F
• Cycle Counter allows for tracking of production quantity
- Viewable by pressing “TIME” and “TEMP” together.
- Reset by pressing the “UP” and “DOWN” arrow keys together for 3 seconds.
• Display
- Toggles to show current Time or Temp setting.
- Visually shows the cycle count down
- Automatically switches to the cycle count down (if showing Temp) when a press cycle is initiated
- Blinks to show the Press is working to reach a new temp setting. (Blinks the actual current temp value, allowing user to monitor progress).
- Blinking stops and alarm chirps to indicate set point is reached
• System Settings Menu allows user control of functions:
- Volume Level – allows adjustment of audible alarm volume
- Alarm On/Off”) – allows first “cycle done” alarm to be muted
- Offset – allows calibration of the Heat Platen to the Display
2. Digital Controller of Heat Platen 
• Digital controller and microprocessor for electronic programming with superior performance and control.
• Efficient 14 x 17 size uses less energy while accommodating 95% of the transfer market size requirements by virtue of the Portrait – Landscape rotation feature.
• Quick preheat to 250 F (15 minutes) allows starting work faster
• Change to new heat settings in 5 minutes allows running different types of transfers without delay
• “SMART” microprocessor - CPU 2.14 constantly monitors and updates Platen temperature readings using STATE OF THE ART RTD SENSOR for temperature stability.
• Temp setting accuracy of +/- 1 degree F minimizes rejects
• Low Alarm - alerts user of below normal temp (200 F)
• High Alarm – alerts user to above normal temp (425 F)
3. Safety Features 
• Allow for a safer work environment.
• 60 seconds late raising Heat Platen - alarm stops and system resets to 210 deg F
• 6 minutes late raising Heat Platen– system shuts down completely
• Auto temperature reduction to 210 F after 180 minutes of inattention.– This feature relates to the press left unattended with the platen in the Up position.
• “Overheat Mode” safety feature setting of 450 F at which point the Press will automatically power down completely. This safety feature will operate regardless of whether the platen is in a raised or lowered position.


|
 |